Products

AC and DC test load

ALB-SR AC three-phase series

ALB-SR AC three-phase series

Download

 


 

 

 

 

◆ Made of stainless steel alloy resistors and high-quality inductors and capacitors。

◆ The discharge power can be set according to the power detection requirements, and can be put in a combination of buttons。

◆ Detect the working efficiency of various power generation equipment and discharge equipment, the maximum output power and load capacity of full load operation。

◆ Simulate various complex working environments, sudden increase and unload of power, and detect the actual loading capacity and efficiency of the discharge equipment。

◆ The use of precise and high-precision load materials can truly simulate the actual load's loading force and the ability to adapt to slight changes in the load。

◆ Emergency stop and temperature protection, overload, short circuit, over-temperature equipment automatically cut off。

◆ Upper limit and lower limit voltage setting, automatically drop to the range voltage point according to the energy (Limited program control machine)。

◆ The AC and DC integrated machine can be customized for users, which can be used for AC, and DC can also be used (customized)。

◆ Temperature protection setting, temperature 0~100° can be set, and real-time temperature condition can be detected at the same time。

◆ Programmable interface 0~30 groups of power and current can be set arbitrarily, the minimum execution time is 1ms and can be cycled 999999 times (limited to program-controlled machine)。

◆ The minimum resolution of the load is 1W, which can accurately simulate the power generation or on-off capability of the product。

◆ It is possible to upload the measurement data to the computer and realize the process record and storage function of the detection process data (only programmable controller)。

◆ There are two operation modes: panel operation or remote control (program-controlled machine only)。

◆ With over-temperature protection function, temperature setting and temperature monitoring。

◆ Customizable power factor 0.3~1 adjustable load。

◆ Used in generators, UPS, switches, fuses, electrical accessories, transformers, temperature rise tests, low-voltage electrical factory inspection, production debugging, simulation of harsh loads,Accurate testing sites for environment, scientific research and development, military industry, etc。

◆ Use button control or switch switch (touch screen control with RS232 communication interface)。

◆ Can measure voltage, current, power, reactive power, active power, apparent power, power factor。

◆ The resistance, inductance, and capacitance can be customized according to the actual needs of users; and the power factor can adjust the test load。

 


 

 

AC power supply/alternator/UPS power supply/inverter/charging pile/switching components and other load test occasions

 

 

 

ALB-S AC series three-phase load

Product model

ALB-SR5

ALB-SR10

ALB-SR20

ALB-SR30

ALB-SR50

Test voltage

AC380V

AC380V

AC380V

AC380V

AC380V

Load nature

Precision R load (constant resistance value) voltage, voltage, rated voltage and current decrease year-on-year

Test power

0.1K-5K

0.1K-10K

0.1K-20K

0.1K-30K

0.1K-50K

Minimum step

0.1K

0.1K

0.1K

0.1K

1K

control method

Manual control

Manual control

Manual control

Manual control

Manual control

Voltage test accuracy

0.5% standard

Current test accuracy

0.5% standard

Frequency power accuracy

0.5%

Voltageandcurrentresolution

V=0.1 I=0.01

I=0.01

R error

2%

2%

2%

2%

2%

Way of working

Long-term

Long-term

Long-term

Long-term

Long-term

Protection level

IP20

Withstand voltage rating

1600V1min

Get out of the linethe way

binding post

Air outlet mode

Bottom in and top out

use life

Operate in accordance with regulations for no less than 10 years

cooling method

Forced air cooling

Forced air cooling

Forced air cooling

Forced air cooling

Forced air cooling

Protective function

 

 

Over temperature alarm

Over temperature alarm

Over temperature alarm

Over temperature alarm

Over temperature alarm

Overcurrent short circuit

Overcurrent short circuit

Overcurrent short circuit

Overcurrent short circuit

Overcurrent short circuit

Short circuit protection

Short circuit protection

Short circuit protection

Short circuit protection

Short circuit protection

the meter shows

Voltage and current

Voltage and current

Voltage and current

Voltage and current

Voltage,current,frequency,power

Auxiliary voltage

AC220V 50HZ

AC220V 50HZ

AC220V 50HZ

AC220V 50HZ

AC220V 50HZ

Size L*W*H

750*480*700

800*480*820

900*650*1000

900*650*1300

Particularity

Non-standard specifications can be customized according to customer requirements

 


接下表:



Productmodel

ALB-SR100

ALB-SR200

ALB-SR300

ALB-SR400

ALB-SR500

Test voltage

AC380V

AC380V

AC380V

AC380V

AC380V

Load nature

Precision R load (constant resistance value) voltage, voltage, rated voltage and current decrease year-on-year

Test voltage

The above specifications are our regular models. For special voltages, please call for consultation. The default is AC380V according to the rising model.

Test power

1K-100K

1K-200K

1K-300K

1K-400K

1K-500K

Minimum step

1K

1K

1K

1K

1K

control method

Manual control

Manual control

Manual control

Manual control

Manual control

Voltage test accuracy

0.5% standard

Current test accuracy

0.5% standard

Frequency power accuracy

0.5%

Voltageandcurrentresolution

V=0.1 I=0.1

R error

2%

2%

2%

2%

2%

Way of working

Long-term

Long-term

Long-term

Long-term

Long-term

Protection level

IP20

Withstand voltagerating

1600V1min

Get out of theline manner

binding post

Air outlet mode

Left in and right out of the wind

use life

Operate in accordance with regulations for no less than 10 years

cooling method

Forced air cooling

Forced air cooling

Forced air cooling

Forced air cooling

Forced air cooling

Protective function

 

 

Over temperature alarm

Over temperaturealarm

Over temperature alarm

Over temperature alarm

Over temperature alarm

Overcurrent short circuit

Overcurrent shortcircuit

Overcurrent short circuit

Overcurrent short circuit

Overcurrent short circuit

Short circuit protection

Short circuit protection

Short circuit protection

Short circuit protection

Short circuit protection

the meter shows

Voltage current frequency power active reactive power factor

Auxiliary voltage

AC220V/380V 50HZ

Size L*W*H

950*940*1600

950*1200*1600

1450*1100*1700

1750*1350*1700

Particularity

Non-standard specifications can be customized according to customer requirements

 


◆ You can contact the company’s technical staff for inquiries and technical support 

◆ The company’s product specifications are continuously developed and improved, and subject to change without notice

◆ For special specifications, please call the business department of the company, and the company accepts special customization for user needs