◆ Adopt advanced direct digital frequency synthesizer (DDS) waveform generation technology, with high frequency stability and good continuity。
◆ High measurement accuracy, suitable for testing current sine half-wave and similar waveforms with DC components。
◆ Provide embedded intelligent PC monitoring system。
◆ Full range adjustable output voltage 0-150V, 0-300V, step distance 0.1V。
◆ Output frequency 45-120Hz (40-500 Hz optional), step distance 0.1 Hz。
◆ Output current limit function。
◆ With 6 groups of memories, you can store commonly used parameters for easy recall during use。
◆ With RS232C communication interface [IEEE488.2 (GPIB) optional], command execution time is less than 1ms。
◆ Protection mode: overvoltage, overcurrent, overload, short circuit, current limit, etc。
◆ Provide readings of root mean square voltage, root mean square current, active power, frequency, power factor, etc。
◆ For 100% load removal, the voltage stabilization response time is within 2ms, the overload capability is strong, and the instantaneous current can withstand 3 times the rated current。
◆ Voltage, frequency, time, digital key input, high accuracy。
◆ Automated test system / Best power supply for R&D unit / 400Hz power supply for military equipment
◆ Computer equipment test / Airport equipment 400Hz power supply / OA product test
◆ Space equipment test / air conditioning equipment test / LCD computer test
◆ Fluorescent lamp rectifier test / various motor products test / switching DC power supply test circuit
◆ Monitor test / Motor equipment test / Transformer/TRIAC/SCR, etc. parts test
ALC2000 programmable single-phase AC power supply
|
model
|
2000
|
2001
|
2003
|
2005
|
2010
|
2015
|
2020
|
2030
|
2050
|
2100
|
2150
|
capacity
|
500VA
|
1KVA
|
3KVA
|
5KVA
|
10KVA
|
15KVA
|
20KVA
|
30KVA
|
50KVA
|
100KVA
|
150KVA
|
Production method
|
SPWM (Sine Pulse Width Modulation)
|
enter
|
Phase
|
1φ2W
|
3φ4W
|
Voltage
|
220V±10%
|
380V±10%
|
frequency
|
47Hz ~ 63Hz
|
Output
|
Phase
|
1φ2W
|
Voltage
|
Low gear 0-150VAC/High gear 0-300VAC Automatic transmission AUTO
|
frequency
|
45~200Hz (40 ~500Hz, 10 ~1000Hz needs to be customized) 0.1Step
|
MaximumphaseCurrent
|
L=120V
|
4.2A
|
8.4A
|
25A
|
42A
|
84A
|
125A
|
168A
|
250A
|
420A
|
840A
|
1250A
|
H=240V
|
2.1A
|
4.2A
|
12.5A
|
21A
|
42A
|
62.5A
|
84A
|
125A
|
210A
|
420A
|
625A
|
Display LCD
|
Voltage, current, frequency, power, power factor PF, peak current AP
|
Power adjustment rate
|
0.1%
|
Hello Elena
|
1 %
|
Total waveform distortion
|
2% (pure resistive load)
|
Frequency stability
|
0.01%
|
Voltage resolution
|
0.1V
|
Frequency resolution
|
0 . 1 Hz
|
Current resolution
|
0.01A
|
0.1A
|
1A
|
Measurementaccuracy
|
Voltage
|
0.5%FS+5dgt
|
Current
|
0.5%FS+5dgt
|
power
|
0.5%FS+5dgt
|
frequency
|
0.01%FS+5dgt
|
Setting accuracy
|
Voltage
|
1%FS
|
frequency
|
0.1%FS
|
Number of storage groups
|
9 groups, each group can memorize voltage and frequency values, and can be easily recalled
|
Number of controllable groups
|
30 groups, each group can run voltage, current, frequency, rise time, running time
|
Communication Interface
|
RS232C [IEEE488.2 (GPIB) optional]
|
Current limit setting
|
O-Max Current
|
protect
|
Over current, over temperature, overload, short circuit
|
weight
|
30
|
50
|
80
|
120
|
150
|
250
|
400
|
600
|
800
|
volume
|
430×177×450
|
430×360×450
|
430×700×550
|
550×700×700
|
700×1350×1418
|
900×1730×1610
|
Operating environment
|
0 ~40℃ 20~80%RH
|