■ Pure power output quality:
110V/220V dual power conversion, providing pure and reliable sine wave (Sine Wave) output. Not only the best source for R&D and laboratories, but also the standard power supply for EMI/EMC and other safety testing.
■ Excellent stability:
The output load voltage is ≤±1%, and the output frequency is ≤±0.01%. The output frequency is generated by a quartz crystal oscillator, which has a very stable and accurate frequency output.
■ High efficiency IGBT module:
Save electricity, energy, and money. The use of insulated gate transistor (IGBT) modules can promote high-power output, improve quality stability, and reduce power loss and interference;
■ Directly select the output frequency file:
47~63Hz, 50Hz, 60Hz (2F, 4F, 400Hz optional) can be used for transformer, coil, etc. for interlayer withstand voltage test.
■ Fast transient response speed:
For 100% unloading/loading, the output load regulation rate (response time) can be immediately stabilized at ±1% (linear load).
■ Strong overload capacity:
100% full load is allowed for long-term use; when the instantaneous load capacity exceeds 3 times the rated current, the power supply can withstand it and will not cause a voltage drop.
■ Multiple safety protection functions:
It has over-voltage, over-current, over-temperature, short-circuit protection and alarm devices. In case of abnormal conditions, the electronic circuit of the machine will automatically sense and immediately cut off the output.
An alarm will be issued at the time to notify the user to deal with an emergency situation.
■ Suitable for various loads:
It can be used for resistive, capacitive, inductive or non-linear loads;
■ High measurement accuracy, suitable for testing of current sine half-wave and similar waveforms with DC components.
■ Customizable analog control for better PC control or program control
◆ Export electrical/electronic/motor manufacturers/replaceable power supply/transformer testing
◆ Compressor/motor related product test/Monitor test
◆ Test of air-conditioning equipment / Test of various electrical products
◆ Fluorescent lamp rectifier test / production plant (quality assurance / control / life test) and other units
◆ Output 400Hz dedicated power supply: military systems, aviation systems, navigation systems, switching power supplies for supercomputers, etc.
◆ Export electrical/electronic/motor manufacturers
ALC1000S standard three-phase AC power supply
|
model
|
1006S
|
1009S
|
1012S
|
1015S
|
1020S
|
1030S
|
1060S
|
1100S
|
1150S
|
1300S
|
1450S
|
capacity
|
6KVA
|
9KVA
|
12KVA
|
15KVA
|
20KVA
|
30KVA
|
60KVA
|
100KVA
|
150KVA
|
300KVA
|
450KVA
|
Production method
|
SPWM (Sine Pulse Width Modulation)
|
enter
|
Phase
|
1φ2W
|
3φ4W
|
Phase voltage
|
220V±10%
|
380V±10%
|
frequency
|
47Hz ~ 63Hz
|
Output
|
Phase
|
1φ2W
|
Voltage
|
Low gear 0-150VAC/High gear 0-300VAC Automatic transmission AUTO
|
frequency
|
45~200Hz (40 ~500Hz, 10 ~1000Hz needs to be customized) 0.1Step
|
Maximumphase Current
|
L=120V
|
16.8A
|
25A
|
33A
|
42A
|
56A
|
84A
|
168A
|
278A
|
420A
|
840A
|
1250A
|
H=240V
|
8.4A
|
12.5A
|
17A
|
21A
|
28A
|
42A
|
84A
|
139A
|
210A
|
420A
|
625A
|
Display LED (Phase A)
|
Voltage, current, frequency, power, power factor PF, peak current AP
|
Power supply voltage regulation rate
|
0.1%
|
Load regulation rate
|
1 %
|
Waveform distortion
|
2% (pure resistive load)
|
Frequency stability
|
0.01%
|
Voltage resolution
|
0.1V
|
Frequency resolution
|
0 . 1 Hz
|
Current resolution
|
0.01A
|
0.1A
|
1A
|
Measurementaccuracy
|
Voltage
|
0.5%FS+5dgt
|
Current
|
0.5%FS+5dgt
|
power
|
0.5%FS+5dgt
|
frequency
|
0.01%FS+5dgt
|
Settingaccuracy
|
Voltage
|
1%FS
|
frequency
|
0.1%FS
|
Number of storage groups
|
M1 (V_F_A), M2 (V_F_A), …M9 (V_F_A)
|
Communication Interface
|
RS232C [IEEE488.2 (GPIB) optional]
|
Current limit setting
|
O-Max Current
|
protect
|
Over current, over temperature, overload, short circuit
|
weight
|
75
|
90
|
120
|
150
|
200
|
300
|
500
|
900
|
1200
|
2000
|
3000
|
volume
|
430×700×700
|
610×930×1050
|
700×1200×1400
|
900×1580×1610
|
100×1580×1800
|
Operating environment
|
0 ~40℃ 20~80%RH
|